3 years ago

Diagnosis of Hirschsprung disease by hydrocolonic sonography in children

Ya Ma, Qian Jiang, Zijian Zhang, Ping Xiao, Yuchun Yan, Junting Liu, Qi Li, Zhengrong Wang

Objectives

To compare hydrocolonic sonography with histopathology for diagnosing children with symptoms highly suggestive of Hirschsprung disease (HD).

Methods

In this prospective study, patients presenting refractory constipation highly suggestive of HD underwent hydrocolonic sonography with retrograde infusion of saline into the colon. The dilated segments, narrowed segments, luminal diameter ratio, transition zone (TZ), thickening, and blood perfusion of the upstream bowel were evaluated. The sensitivity and specificity of combined and single parameters were determined in comparison with biopsy.

Results

One hundred and three children were included in this study; 49 were confirmed to have HD. The luminal diameter ratio showed superiority over other parameters. An area under the curve (AUC) of 0.969 (95% confidence interval [CI]: 0.936–1.000) and a cutoff value of 1.51 were established by receiver operating characteristic (ROC) curve analysis of the luminal diameter ratio (sensitivity: 89.8%; specificity: 96.3%). By combining the luminal diameter ratio as the major criterion with two minor criteria, hydrocolonic sonography showed the same sensitivity (91.8%) and better specificity (96.3% vs 87%) than contrast enema, but this difference was not statistically significant (p = 0.063). Consistency analysis showed a kappa value of 0.825 (p < 0.001), indicating excellent agreement between hydrocolonic sonography and contrast enema.

Conclusions

Hydrocolonic sonography is a valuable diagnostic tool with both high sensitivity and specificity for HD diagnosis, allowing morphological and vascular assessments of the colon, and correlates well with contrast enema. In the appropriate setting, hydrocolonic sonography may be an alternative screening method for HD in a large group of children with constipation.

Key Points

Hydrocolonic sonography is a simple, well-tolerated diagnostic tool with both high sensitivity and specificity for HD diagnosis.

Hydrocolonic sonography allows morphological and vascular assessments of the colon, and correlates well with contrast enema.

Hydrocolonic sonography is a possible alternative modality for paediatric patients highly suggestive of HD.

You might also like
Discover & Discuss Important Research

Keeping up-to-date with research can feel impossible, with papers being published faster than you'll ever be able to read them. That's where Researcher comes in: we're simplifying discovery and making important discussions happen. With over 19,000 sources, including peer-reviewed journals, preprints, blogs, universities, podcasts and Live events across 10 research areas, you'll never miss what's important to you. It's like social media, but better. Oh, and we should mention - it's free.

  • Download from Google Play
  • Download from App Store
  • Download from AppInChina

Researcher displays publicly available abstracts and doesn’t host any full article content. If the content is open access, we will direct clicks from the abstracts to the publisher website and display the PDF copy on our platform. Clicks to view the full text will be directed to the publisher website, where only users with subscriptions or access through their institution are able to view the full article.